This link includes 2 units of LS-RDIO0202, 1W power output. used for pump wireless control.
LS-RDIO0202 Modbus RTU is a 1W I/O module, 2 isolated digital inputs, 2 isolated relay outputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for pump control, water level monitoring, motor, valve, light ON-OFF control.
Transparent I/O System, no programming required
Not need internet, no third party cell, no monthly fees
You have full control over your own carrier
Real time status feedback from the remote site
Fast installation and easy setup
Parameter:
Input: 2 isolated digital active inputs (passive input customize)
Output: 2 isolated relay passive contact outputs (active output customize), contact max load 5A@220V AC, 5A@30V DC.
Communication: RS485 (wireless RS485customize)
Protocol: Modbus RTU
Collocated with a wireless data module whose transmitting distance is about 2km-3km. The working frequency 433MHz (400-470MHz); RF power: 1W; Receiving sensitivity: -123dBm
Receiving current:<50mA; transmitting current: 600mA
Power supply: DC 9V-36V
Dimension: 115mm90mm40mm
About the DIP switch
1) Outer(right side) DIP 1-4 are used for channel setting. Please check the following definition:
Channel No. | DIP Setting | Channel No. | DIP Setting | Channel No. | DIP setting | Channel No. | DIP setting |
1 | 1234 | 2 | 1234 | 3 | 1234 | 4 | 1234 |
5 | 1234 | 6 | 1234 | 7 | 1234 | 8 | 1234 |
2) Outer(right side) DIP 5-8 are used for mode setting. Please check the following definition
DIP | Status | Function | Remarks |
5 | OFF | With feedback | |
ON | No feedback mode | remote side DI, this side only DO | |
6,7 | OFF,OFF | 1 to 1 control | Master set ID to X, Slave module's ID set to X (ie. master ID1, slave ID1. remember set ID the same) |
6,7 | ON,OFF | 1 to 2 slaves control | Master set to ID1, 2 slave modules' ID set to 1 and 2 respectively |
6,7 | OFF,ON | 1 to 4 slaves control | Master set to ID 1, 4 salve modules' ID set to 1, 2, 3 and 4 respectively |
6,7 | ON,ON | 1 to 8 slave control | Master set to ID 1, 8 slaves' ID set to 1, 2, 3, 4, 5, 6, 7 and 8 respectively |
8 | OFF | Slave mode | |
ON | Master mode |
3) Interior(left side)DIP 1-8 are used for module's ID setting (also Modbus slaves' ID.), for example
ID | DIP setting | ID | DIP setting | ID | DIP setting |
1 | 2 | 3 | |||
4 | 5 | 6 | |||
7 | 8 | 9 | |||
10 | 11 | 12 | |||
13 | 14 | 15 | |||
DIP for slaves with ID 16-254, please refer the above regulation to set |
Note: Above picture of sample is ID1
Application:
Lighting Control Systems
Wireless Pump Control
Wireless Valve Actuation
Conveyor Control
Grain Augers
Engine Control
Tank Level Monitoring
PLC Activation
SCADA
Advantage of wireless solution
No wires to bury or maintain, no need to drill holes on wall
Reliable communication in all direction,any terrain, regardless of hills, walls, trees
Cost saving in installation and maintenance
Radio based, no need internet and monthly fee, full ownership of the system
Wireless RTU features
- Portable device, DIN-rail mounting for easy installation
- Isolated inputs
- LEDs for power supply, communication, input, output status
- Flexible networking, point to point or point to multipoints
- DIP to change different modes
- Different types of I/O, DI, DO, AI, AO are available
- I/O expandable
- Short delay time
- Support I/O reduction, field input, remote output
- Easy handing on RS485 network, support Modbus RTU protocol
- Support on-line upgrade. Can configure by customer in setting mode